par Ackermann, Markus;Atz, S.;Aulchenko, Vladimir;Bachmann, Sebastian;Baiboussinov, B.;Barthe, Sylviane;Beaumont, Will;Beckers, Thomas;Beissel, Franz;Benhammou, Yan;Bergdolt, A.M.;Bernier, K.;Bluem, P.;Bondar, Alexander ;Bouhali, Othmane ;Stefanescu, Jacqueline ;Vander Velde, Catherine ;Vanlaer, Pascal ;Van Lancker, Laurent H.C.-P. ; [et al.]
Référence Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 436, 3, page (313-325)
Publication Publié, 1999
Référence Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 436, 3, page (313-325)
Publication Publié, 1999
Article révisé par les pairs
Résumé : | In order to check the system aspects of the forward-backward MSGC tracker designed for the future CMS experiment at LHC, 38 trapezoidal MSGC counters assembled in six multi-substrates detector modules were built and exposed to a muon beam at the CERN SPS. Results on the gain uniformity along the wedge-shaped strip pattern and across the detector modules are shown together with measurements of the detection efficiency and the spatial resolution. |