par Bouhali, Othmane ;De Lentdecker, Gilles ;Dewéze, S.;Udo, Fred;Van Doninck, Walter;Vander Velde, Catherine ;Van Lancker, Luk;Zhukov, Valéry ;Boulogne, Isabelle ;Daubie, Evelyne
Référence Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 459, 1-2, page (211-220)
Publication Publié, 2001-02
Référence Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 459, 1-2, page (211-220)
Publication Publié, 2001-02
Article révisé par les pairs
Résumé : | This article introduces the MICROMEGEM detector, a position-sensitive proportional gas counter produced using advanced Printed Circuit Board (PCB) technology. The detector is equipped with a Gas Electron Multiplier (GEM) foil placed 50 μm above a plane of pick-up strips. The GEM produces a first gas amplification which is extended below the GEM foil by applying a strong electric field between the strips and the lower electrode of the GEM. The array of strips is used for read-out to obtain 1-D positional information. We present results on the gas gain, the energy resolution and the rate capability. The behaviour in an intense beam of 300 MeV/c pions in presence of heavily ionizing particles has also been investigated. |