par Jonckheere, Robert
Référence Journal of fluids engineering, 97, 2, page (256-258)
Publication Publié, 1975
Article révisé par les pairs
Résumé : A new analytical method is presented, allowing direct, easy and accurate computation of the nonlinear waterlevel oscillations occurring in a simple surge tank under instantaneous load rejection. The method yields several design equations and is also applicable in the case of instantaneous load demand and to other types of surge tanks. © 1975 by ASME.