par Abbaneo, Duccio;Barria, Patrizia ;De Lentdecker, Gilles ;Lenzi, Thomas ;Maerschalk, Thierry ;Verhagen, Erik ;Yifan, Yang ;Yonamine, Ryo ;Zenoni, Florian ; [et al.]
Référence Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 845, page (313-317)
Publication Publié, 2017-02
Article révisé par les pairs
Résumé : This contribution introduces a new type of Micropattern Gaseous Detector, the Fast Timing Micropattern (FTM) detector, utilizing fully Resistive WELL structures. The structure of the prototype will be described in detail and the results of the characterization study performed with an X-ray gun will be presented, together with the first results on time resolution based on data collected with muon/pion test beams.