par Manfredi, Gabriele
;Lim, Jun;Rosseel, Kris;Van den Bosch, Joris;Aerts, Alexander;Doneux, Thomas
;Buess Herman, Claudine 
Référence EUROSENSORS 2014(XXVIII edition of the conference series), Procedia Engineering, Elsevier, Vol. 87, page (264-267)
Publication Publié, 2014



Référence EUROSENSORS 2014(XXVIII edition of the conference series), Procedia Engineering, Elsevier, Vol. 87, page (264-267)
Publication Publié, 2014
Publication dans des actes
Résumé : | Potentiometric oxygen sensors with LBE/PbO and In/In2O3 reference electrodes coupled with yttria partially stabilized zirconia(YPSZ) have been developed for use in liquid lead-bismuth eutectic (LBE) over the temperature range from 200 to 450 °C. Theperformance of sensors with LBE/PbO and In/In2O3 reference electrodes was evaluated comparing the oxygen activity measuredin oxygen saturated LBE (from 200 to 450 °C) with these sensors to the one measured by sensors with Bi/Bi2O3 and air/LSM(strontium-doped lanthanum manganite) electrodes, using same solid electrolyte and measurement setup. The sensors withLBE/PbO and In/In2O3 reference electrode performed well down to 200 °C while the sensor with Bi/Bi2O3 showed significantdeviations at 200 °C. |