Résumé : Glomerular filtration rate (GFR) may be computed using the kinetics of the renal distribution volume curve Vt = Rt/Pt and a power fit of the plasma curve Pt = Pot-B. It can be demonstrated that GFR = d(Vt)/d(t)(1-B). The method is largely independent of background subtraction, allowing nonequivocal renal function determination in all cases. In a preliminary series of 20 patients, the linear regression coefficient of computed GFR with true clearance measurement by multiple blood samples method was 0.97 with a standard error on the estimate of the clearance of 5.5 ml.