par Piepsz, Amnon ;Tondeur, Marianne ;Ham, Hamphrey
Référence The Journal of nuclear medicine, 40, 6, page (972-976)
Publication Publié, 1999-06
Article révisé par les pairs
Résumé : The aim of this study was to estimate the reproducibility and accuracy of 99mTc-mercaptoacetyltriglycine (MAG3) relative percentage uptake. Methods: Reproducibility was evaluated on healthy volunteers who were submitted twice to a 99mTc-MAG3 renographic study, which used different uptake algorithms, different background corrections and different time intervals. Accuracy was evaluated in a group of patients with symmetrical or asymmetrical relative renal function, who underwent both 99mTc- dimercaptosuccinic acid (DMSA) and 99mTc-MAG3 studies, using the DMSA relative percentage uptake as a reference. Results and Conclusion: The methods that combined the best reproducibility and accuracy for estimating 99mTc-MAG3 left-to-right uptake ratio were the integral method, with subrenal or perirenal background correction, and the Patlak-Rutland plot. The use of the integral method without background correction introduced a systematic bias, whereas the slope method resulted in high variability. Therefore these methods cannot be recommended.