Articles dans des revues avec comité de lecture (128)
60.
Diciotti, S., Nobis, A., Ciulli, S., Landini, N., Mascalchi, M., Sverzellati, N., & Innocenti, B. (2017). Development of digital phantoms based on a finite element model to simulate low-attenuation areas in CT imaging for pulmonary emphysema quantification. International Journal of Computer Assisted Radiology and Surgery, 12(9), 1561-1570. doi:10.1007/s11548-016-1500-661.
Belvedere, C., Leardini, A., Catani, F., Pianigiani, S., & Innocenti, B. (2017). In vivo kinematics of knee replacement during daily living activities: Condylar and post-cam contact assessment by three-dimensional fluoroscopy and finite element analyses. Journal of orthopaedic research, 35(7), 1396-1403. doi:10.1002/jor.2340562.
Verdini, F., Zara, C., Leo, T., Mengarelli, A., Cardarelli, S., & Innocenti, B. (2017). Assessment of patient functional performance in different knee arthroplasty designs during unconstrained squat. Muscles, Ligaments and Tendons Journal, 7(3), 514-523. doi:10.11138/mltj/2017.7.3.51464.
Vetrano, M., Frizziero, A., Gasparre, G., Via, A. G., Innocenti, B., Longo, U. G., Mahmoud, A., Masiero, S., Mazza, D., Natali, S., Notarangelo, C., Oliva, F., Osti, L., Padulo, J., Pellicciari, L., Perroni, F., Piccirilli, E., Ramponi, C., Salvatore, G., Panni, A. S., Suarez, T., Tarantino, U., Bisicchia, S., Vittadini, F., Vulpiani, M. C., Ferretti, A., Maffulli, N., Bossa, M., De Carli, A., Di Lorenzo, L., Erroi, D., Forte, A., & Foti, C. (2017). I.S.Mu.L.T. First-time patellar dislocation guidelines. Muscles, Ligaments and Tendons Journal, 7(1), 1-10. doi:10.11138/mltj/2017.7.1.00166.
El-Zayat, B. F., Heyse, T. J., Fanciullacci, N., Labey, L., Fuchs-Winkelmann, S., & Innocenti, B. (2016). Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study. Archives of orthopaedic and trauma surgery, 136(12), 1741-1752. doi:10.1007/s00402-016-2571-067.
Severijns, P., Vanslembrouck, M., Vermulst, J., Callewaert, B., Innocenti, B., Desloovere, K., Vandenneucker, H., & Scheys, L. (2016). High-demand motor tasks are more sensitive to detect persisting alterations in muscle activation following total knee replacement. Gait & posture, 50, 151-158. doi:10.1016/j.gaitpost.2016.09.00370.
Pianigiani, S., Vander Sloten, J., Pascale, W., Labey, L., & Innocenti, B. (2015). A new graphical method to display data sets representing biomechanical knee behaviour. Journal of Experimental Orthopaedics, 2(1), 18, 1-8. doi:10.1186/s40634-015-0034-071.
Diciotti, S., Nobis, A., Ciulli, S., Landini, N., Mascalchi, M., Sverzellati, N., & Innocenti, B. (2015). Development and analysis of a finite element model to simulate pulmonary emphysema in CT imaging. Conference proceedings, 2015-November, 7319850, 6370-6373. doi:10.1109/EMBC.2015.7319850