par Kobayashi, Makoto;Settles, Ronald Dean;Sugiyama, A.;Takahashi, Tohru;Tian, Junping;Watanabe, Takashi;Yonamine, Ryo ;Ogawa, T;Kawaguchi, Takeshi;Fujii, Keisuke;Fusayasu, Takahiro;Ikematsu, Katsumasa;Kato, Yukihiro;Kawada, Shinichi;Matsuda, Takeshi
Référence Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 845, page (236-240)
Publication Publié, 2017-02
Référence Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 845, page (236-240)
Publication Publié, 2017-02
Article révisé par les pairs
Résumé : | We have developed a novel technique for the measurement of the avalanche fluctuation of gaseous detectors using a UV laser. The technique is simple and requires a short data-taking time of about ten minutes. Furthermore, it is applicable for relatively low gas gains. Our experimental setup as well as the measurement principle, and the results obtained with a stack of Gas Electron Multipliers (GEMs) operated in several gas mixtures are presented. |