Article révisé par les pairs
Résumé : We present a complete study on four methane lines for two atmospheric micro-windows (in the ν2 + ν4 absorption band) used for the determination of atmospheric methane concentrations with ground-based Fourier transform spectrometers. Thanks to our tunable diode laser (TDL) spectrometer with active wavenumber control and step-by-step recording mode we have improved the accuracy on intensity, broadening, narrowing, and pressure shift parameters. To make our results directly useable in atmospheric models which usually assume a Voigt line shape, we have parameterised an effective-broadening parameter γVoigt (P) for each line and each gas mixture (CH4-N2 and CH4-O 2). When this parameterisation is used to fit a "true" line profile, the same concentration as with more sophisticated models is retrieved using a consistent set of spectroscopic parameters in both approaches. © 2005 Elsevier Inc. All rights reserved.